Specification (mm) | Compressive Strength(MPa/m³) | Average Density(kg/m³) | |
Average Value | Min Value | ||
600*40*200 | ≥2.0 | ≥1.6 | ≤425 |
600*50*200 | ≥2.0 | ≥1.6 | ≤425 |
600*75*200 | ≥2.0 | ≥1.6 | ≤425 |
600*100*200 | ≥2.0 | ≥1.6 | ≤425 |
Performance | B04 Grade | B05 Grade | B06 Grade | |
Dry Density(kg/m³) | ≤425 | ≤525 | ≤625 | |
Compressive Strength(Mpa/m³) | A2.0 | A3.5 | A5.0 | |
Thermal Conductivity(W/(m*K) | 0.09 | 0.12 | 0.132 | |
Drying Shrinkage(mm/m) | 0.3 | 0.3 | 0.32 | |
Freezing Resistance | Quality Loss(%) | ≤3 | ≤3 | 2.1 |
Strength after Freezing(Mpa) | ≥2.0 | ≥3.0 | 4.4 | |
Softening Factor | 0.88 | |||
Penetration Resistance | 88.3 | |||
Fire Resistance( Hour) | 4hour( Block Wall Thickness:100mm) | |||
Average Sound Insulation(dB) | 40.8(Block thickness:100mm, with double sides putty) | |||
Size Deviation(mm) | Length±2, Width±1, Thickness±1 |
Ecotrend AAC Thermal Insulation Block is widely used as external wall blocks insulation layer to provide the building performance on heat insulation.